Integrated bypass contactors reduce energy losses and the connection is simplified, and setup is child's play thanks to the restriction to just three potentiometers. The optimized ramp properties nevertheless ensure a very smooth start and stop under Allen operating conditions. Dimensions Width of the product: 54,000 mm Product height: 187,000 mm Depth of the product: 153,000 mm Net weight: 1 kg Technical specifications Rated operational voltage: 208 600 V AC Rated control supply voltage (Us): 24 V AC / DC Rated control voltage (Uc): DC operation 24 V Rated operational power - in-line connection (Pe): (230 V) 11 kW (400 V) 22 kW (500 V) 30 kW Rated operational current - in-line connection (Ie): 45 A Service factor in%: 100% Overload protection: Recommended MS450 36 45 Integrated electronic overload protection: No Starting power at max.
Rated current Ie: 4xIe for 6s Ramp time: During start 1... 10 seconds During stop 0... 20 second (s) Initial voltage for starting: 40... 70% Specially designed ramp with stair tension: 100... 60% Current limiting function: No Switch for changing to delta connection: No Relay for signal "Run": Yes Bypass signal relay: Yes Error relay: No Overload signal relay: No LED display "start ramp completed": green LED display "ready to start / ON": Green LED display "Run": Green LED display "start / stop": green Number of starts per hour at 3.5 Ie for 7 seconds.
At 50% on 50% off: 10 Communication: FiledBusPlug (optional) Protection class: according to IEC 60529, IEC 60947-1, EN 60529 main connection terminals IP10 Connection type: Screw terminals Connection possibility main circuit: Rigid 1x6... 16 mm² Connection possibility control circuit: 1 x 0.75... 2.5 mm² Rigid 2 x 0.75...
2.5 mm² Connection option supply circuit: Rigid 1x0.75... 2.5 mm² Rigid 2x0.75... 2.5 mm² Tightening torque: Main circuit 8 Nm Supply circuit 0.6 Nm Control circuit 0.6 Nm Model series: PSR45. New goods in original packaging.
FIG Dimensions 54,000 mm Product height: 187,000 mm 153,000 mm Net weight: 1 kg Technical specifications 208 600 V AC 24 V AC / DC (230 V) 11 kW (400 V) 22 kW (500 V) 30 kW 45 A Service factor in%: 100% Overload protection: No 4xIe for 6s Ramp time: 40... The item "ABB Stotz-Kontakt Soft Starter PSR45-600-11 Soft Start 1SFA896111R1100 New+Boxed" is in sale since Monday, October 12, 2020. This item is in the category "Business, Office & Industrial\Industrial Automation & Motion Controls\Drives & Starters\Starters\Reduced Voltage/Soft Starters". The seller is "knoeken" and is located in Einbeck. This item can be shipped to European Union member countries.